IO-Digital8 Sensor - IO-Digital8 sensor with 8 ALARM/NORMAL indication

IO-Digital8 Sensor

IO-Digital8 sensor with 8 ALARM/NORMAL indication

The dry contacts can be configured as inputs or outputs and the IO-digital8 is user definable so it can be used to detect many different inputs.

  • Product Code: IODC8
  • MSRP Price:
  • Powered by the base unit

IO-Digital8 sensor with 8 ALARM/NORMAL indication in the AKCess Pro securityProbe 5E web interface. Can have 8 dry contacts on one Intelligent Sensor port. The main housing can be mounted on a wall and a standard CAT5 cable can be run to the intelligent sensor port on the securityProbe 5E.

There are two versions of the IO-digital8 depending on your requirements.

The first version has a single RJ45 connector at one end and 8 x 2 pin dry contact connectors along one side.

The second unit also has a single RJ45 connector at one end but the 8 x 2 pin dry contact connectors are replaced by two RJ45 connectors, each compatible with 4 dry contacts.

The dry contacts can be configured as inputs or outputs and the IO-digital8 is user definable so can be used to detect many different inputs such as UPS status, security systems, alarm panels or air conditioning status.

Specifications

Measurement range : Alarm or Normal
Communications cable : RJ45 jack to sensor using UTP Cat 5 wire, Maximum extension cable length 305m (1000 ft.) with approved low capacitance shielded cable or UTP
Sensor type : Open/closed or cycles contact switches
Input voltage range : 0 to 5 volts on each of the 8 dry contacts
Current Range : Can sink up to 20 mAmps on each of the 8 dry contacts
Measurement rate : Multiple readings every second
Power source : Powered by the securityProbe 5E. No additional power needed
Normal input voltage is settable under software on each of the 8 dry contacts
Normally open, normally closed is settable under software on each of the 8 dry contacts
Only compatible on AKCess Pro securityProbe line of units
securityProbe 5E autodetects the presence of each dry contact on the IO-digital8
Connect up to 8 IO-digital8 sensors per each securityProbe 5E main unit and E-sensor8 expansion modules for a total of 64 dry contacts per box
Full autosense including disconnect alarm
  • SNMP interface for alarm/normal status
  • SNMP traps sent when critical
  • SNMP polling via get command
  • When an alarm condition is activated the description and location of the fault can be sent via email, SMS, MMS, Skype, phone calls and other advanced notifications from the securityProbe 5E’s web interface
  • Each of the 8 dry contacts on the IO-digital8 sensor can also be configured as outputs either 0 VDC or 5 VDC and can sink up to 20 mA of current when connected to a load