The AKCP Dry Contact sensor provides seamless integration with burglar alarms, fire alarms, and any other third-party equipment requiring monitoring via the sensorProbe+. Highly versatile and user-configurable, these general-purpose I/O pins can detect a wide range of inputs, including UPS status, security system alerts, and HVAC conditions.

Key Features:

  • Dual I/O Functionality: Pins can be configured as either an input or an output.

  • Configurable Output: When functioning as an output, the sensor can source up to 20mA. Output voltage is software-selectable between 0V (Low) and 5V (High).

  • State Retention (SNMP): To ensure no critical events are missed, input switches latch onto error conditions. If an input encounters a critical state, it retains that status until read via SNMP, guaranteeing the event is reported before the sensor resets to normal.

  • Flexible Input Detection: Easily monitor the open or closed state of external switches. Combined with third-party sensors, input pins are ideal for monitoring door and window contacts, water incursion, and other critical environmental variables.

Measurement RangeInput: Alarm or Normal
Output : Set or Reset
Sensor TypeInput : Open / Closed contact switch
Output : High (5V) / Low (GND)
Contact voltage range5 volts pulled-up dry contacts*
Input Measurement RateMultiple readings every second
 Normal input state is settable under software
Electrical OutputCan sink up to 20mA**, when set to Low
  
Interface 
Communications CableRJ-45 jack to sensor using UTP Cat 5 wire
Communications Cable Max. length1000 Ft (305m) with approved low capacitance shielded cable or UTP
Power SourcePowered by the base unit. No additional power needed
 Full auto-sense including disconnect alarm
Important Note*Dry Contacts are not isolated, don’t connect any voltage source
** Dry contact output is not suitable for directly driving a relay
Sensor count1

Schedule a Demo With Us

Find out how we can Protect, Monitor and Optimize your Data Center

AKCP data center monitoring sensors

Interested in our FREE Data Center PUE check?

Contact us below and schedule a 15 minute consultation

Thank you for your submission!

One of our team members will reach out within 24 hours.

Contact AKCP