Home » Contactless Current Meter

Power Monitoring

Contactless Current Meter

Measure current. Keep cables intact

Monitor multicore power cables up to 32A

AKCP Contactless Current Meter (CCM)
multicore single phase cables

Multicore Sensing

For 2 core and 3 core single phase cables, no need to cut

Amperes icon

Up to 32A

Made to clamp around cables up to 32A

Autosense sensor port

Base Unit Powered

Automatically detected, powered and configured when plugged in

Capacity planning icon

Capacity Planning

Monitor rack power capacity usage and plan for new loads

Current Monitoring Without Cutting Wires

The CCM senses current through multicore sheath without needing to access individual wire

multicore cable monitoring diagram

Most current transformers require you to have access to an individual wire. This is not practical where you have the live, neutral and earth wires in a single sheath. The AKCP Non-Invasive current meter allows you to monitor current (and power if you have a reference voltage) in 2 core or 3 core cables. Our unique
current measurement technology makes measuring individual IT rack current and power simpler, and lower cost than ever before.

Combine the Non-Invasive current meter with cabinet thermal map sensors. Using our Quicklime Server combine current load, thermal map and differential air pressure and analysis.

• No downtime for installation
• No electrician required
• Input for PUE calculations
• Rack level current monitoring
• Accurate +/- 5%
• Input for AKCP sensorCFD

From Cable to Current

Connect the CCM to a compatible AKCP sensorProbe+ base unit for LAN or Wan monitoring

how to connect the CCM to sensorProbe+

Accuracy Depends on Calibration

Choose the calibration approach that meets your monitoring requirements

Status IndicationLED indication for power
LED array for calibration
InputsMagnetic field sensing of current in multicore cable
Accuracy+/-5% when factory calibrated on cable of same type
+/-10% on non-factory calibrated cable
ComponentsManufactured using highly integrated, low power surface mount technology to ensure long term reliability.
Operating EnvironmentTemperature: Min. -35°C Max. 80°C
Humidity: Min. 20% – Max. 80% (Non-condensing)
Interface 
Communications Cable:RJ-45 jack to sensor using UTP Cat 5e cable
Power SourcePowered by the controller unit. No additional power needed
Power Consumption:Typical 7.25mWatt, 1.45mA
Maximum Cable Length:50ft using standard CAT5/6 UTP cable
Dimensions:49(W) x 45(H) x 51(D) mm
MountingCable mounted
Sensor Count1

Schedule a Demo With Us

Find out how we can Protect, Monitor and Optimize your Data Center

AKCP data center monitoring sensors

Interested in our FREE Data Center PUE check?

Contact us below and schedule a 15 minute consultation

Thank you for your submission!

One of our team members will reach out within 24 hours.

Contact AKCP