How Computational Fluid Dynamics Simulation Helps Data Center Design

Clarissa GarciaArticles, Blog

computational fluid dynamics simulation in data center

According to a recent Frost & Sullivan market research analysis, the data center market would be worth $432.14 billion per year by 2025. This is up from $244.74 billion in 2019, indicating a 10% annual growth rate. Datacenter operators, builders, and designers will expand their investment to leverage the deployment and use of IoT, Big Data, and AI. Emerging economies are predicted to grow rapidly, with the Asia-Pacific area leading the way. DatacenterComputational Fluid Dynamics analysis can help meet green data center targets while expanding their capacity.

This involves making energy and resource efficiency a top concern when developing and operating data centers. A slight boost in overall system efficiency can boost a data center asset’s return on investment significantly. Data centers have traditionally been extremely energy-intensive, with the majority of cooling provided by electricity-hungry chillers and other related equipment. The use of natural heat sinks such as the surrounding air or a water supply has become increasingly popular in recent years. To reduce energy demands for thermal management, many data centers have been built in cooler climes, and some net-zero data center operations even transfer extra heat to meet adjacent heat demands. Many data centers have been built in cooler areas to reduce energy demands for thermal management, and some net-zero data center operations even transfer extra heat to fulfill adjacent heat demands, such as houses and offices.

Driven By Simulation

More precise simulation models of how the system operates have enabled current advances in more energy-efficient data centers. The major energy and environmental aspects of a given design can be captured through simulation and modeling of a data center building, equipment, and operation. The performance of this model is then predicted in the real world by simulating it against a set of climate and other variables. Designers can use simulation tools to undertake several design iterations and determine a building’s rigorous and physics-based probabilistic performance. This necessitates the use of analysis software that takes into consideration the physics of heat transport, cooling, ventilation, and other product and material qualities. A fundamental benefit of modeling is options analysis at an early stage of design to swiftly examine multiple designs before the design gets too intricate and impossible to change. A sort of study performed by engineers to analyze and simulate the performance of data centers is engineering simulation.

Engineering Simulation On The Cloud

computational fluid dynamics simulation process

Photo Credit: blogspot.com

Computational Fluid Dynamics (CFD) is a sort of engineering simulation that simulates the behavior of fluids. To mimic the physical and thermal parameters of a data center setup, for example, a 3D model of a data center is employed. Computational Fluid Dynamics (CFD) can simulate the basic heat transfer mechanisms — conduction, convection, and radiation — and show how they affect the thermal performance of any building or piece of equipment. ‌The approach is made possible by a cloud-based data center CFD simulation platform that can execute several simulations at the same time. This cuts down on the time it takes to thoroughly investigate all of the necessary scenarios within a problem domain, which can number in the hundreds. All conceivable design situations can be simulated at the same time using parallel run capabilities. Computational Fluid Dynamics CFD is helpful in gaining a better understanding of:
  • Existing designs’ flow characteristics expose inefficiencies. Recirculation and isolation zones between aisles, or CRAC units, for example.
  • Temperature distribution across different sites.
  • The temperature of the equipment.
  • Zones or hotspots are identified.
  • What-if scenarios and design tweaks are compared.

Computational Fluid Dynamics (CFD) Simulation Best Practices

Several publications on Computational Fluid Dynamics (CFD) Simulation Best Practices have been published in recent years. These suggestions are usually aimed toward CFD simulation analysts with complete control over mesh production and solver options. Nonetheless, users of application-specific software should be aware of a few best practices that will help them succeed. Here’s a quick rundown:
  • Make Sure Your Setup Is Correct
The need to press the simulate button is understandable. Remember, that considerable simulation power comes with great responsibility. Make sure that geometry, mesh, and initial/boundary conditions are correct, and that your setup is physically and numerically sound. You’ll save a lot of time if you can avoid these early setup mistakes.
  • Gradually Increase The Level Of Complexity
Breaking down your problem into manageable chunks and gradually increasing simulation complexity is generally beneficial.
Another issue to evaluate is the physical models’ relevance. While it’s understandable to want to get as near to reality as possible, will activating surface tension be feasible when simulating a tens-of-kilometer-long river flow problem?
  • Make the Most of Your Monitoring Software
Even before you start conducting simulations, you can start optimizing your system. It’s critical to understand how to make the most of the capabilities included in your Computational Fluid Dynamics (CFD) program. Many simulation software packages include built-in features to assist you in diagnosing and improving your simulations on the fly. The simulation monitor gives you useful information on convergence, performance, numerics, and flow characteristics, while the runtime options let you customize your simulation as it runs. When things start to go wrong, keep in mind that these characteristics can save the day.
  • Enlist The Help of the Experts
Software support exists for a purpose, and any competent Computational Fluid Dynamics (CFD) firm should have a strong support organization. Support engineers are well-versed in the program and can spot obvious flaws or provide innovative solutions to any issues you may be experiencing. They can provide insights into your challenges and provide you with better ways to tackle them because they’ve seen a wide range of applications.
  • Allow it to be alone
Then sit back, unwind, and quit fiddling with your simulation. Looking at your simulation output actually modifies the findings, which is a little-known truth.

Benefits of data center Computational Fluid Dynamics Simulation

Obstructions Within The Cabinet

Cabling or other obstructions can impede the flow of air causing high-temperature differentials between the inlet and outlet temperatures. The cabinet analysis sensor with pressure differential can also help analyze airflow issues.

Server And Cooling Fan Failures

As fans age, or fail, the airflow over the IT equipment will lessen. This leads to higher temperature differentials between the front and rear.

Insufficient Pressure Differential To Pull Air Through The Cabinet

When there is an insufficient pressure differential between the front and rear of the cabinet, airflow will be less. The less cold air flowing through the cabinet, the higher the temperature differential front to rear will become.

Power Usage Effectiveness (PUE)

When the data is combined with the power consumption from the in-line power meter you can safely make adjustments in the data center cooling systems, without compromising your equipment, while instantly seeing the changes in your PUE numbers.

ACKP Sensors And Central Monitoring

Wired and Wireless Thermal Map Sensors

Cabinet Analysis and Thermal Map Sensors

Cabinet Analysis and Thermal Map Sensors

Sensors placed in the room or on individual cabinets have traditionally monitored the temperature and humidity within data centers. The Thermal Map sensor, wired or wireless, is a three-in-one sensor that monitors temperature and humidity at the top, middle, and bottom of your server cabinet. Designed to be installed at the rack’s front air inlet, with a second sensor installed at the back air outlet.

AKCPro Server

AKCPro Server is our world-class central monitoring and management software. Suitable for a wide range of monitoring applications. Free to use for all AKCP devices. Monitor your infrastructure, whether it be a single building or remote sites over a wide geographic area. Integrate third-party devices with, Modbus, SNMP, and ONVIF compatible IP cameras.

Monitor all your AKCP devices

All deployed AKCP base units and attached sensors can be configured and monitored from AKCPro Server (APS). Base units communicate with the server through your wired local network (LAN) or wide area network (WAN). Remote sites with no wired network send data to the server through the cellular data network via a VPN connection.

Conclusion

Engineers can use Computational Fluid Dynamics (CFD) simulation to swiftly model a variety of data center architecture configurations. More significantly, it enables a designer to correctly assess the data center’s thermal, airflow, layout, and equipment performance. Correctly defined models and engineering simulation software are powerful tools in the design of future data centers because accurately anticipating a system’s performance gives critical information that feeds into financial considerations such as return on investment and payback.